Mfg Part Number: NES-4107 | Alternate P/N: NES4107 | Manufacturer: Newton Engineering Service Inc |
NSN : 5950-00-237-1073 | Item Name : transformer power | CAGE Code : 86632 |
FSC : 5950 Coils and Transformers |
The NSN 5950-00-237-1073 products that we feature by MFG Newton Engineering Service Inc are paired alongside CAGE Code 86632 for NES-4107 NSN Part Number. Emergent Purchasing utilizes CAGE Codes, allowing our customers to narrow down our vast listing by using our optimized search engine. If you are familiar with the CAGE Codes associated with the particular NSN products you wish to purchase, we invite you to use them. If you have more information regarding the NSN components you wish to purchase, please provide such details in an RFQ form. When you fill out a form for NES-4107, in return, you will be provided a competitive quote for your comparisons in just 15 minutes or less.
Thank you for choosing to rely on Emergent Purchasing for all your operational needs. You have reached our NSN RFQ page featuring highly sought-after NSN 5950-00-237-1073 parts and components with Transformer Power manufactured by MFG Newton Engineering Service Inc. Some of these items include part number NES-4107 under FSC5950 Coils and Transformers, and various others, all of which have been subjected to a myriad of quality assurance measures, tests, verifications, and assessments. At Emergent Purchasing, we make it our priority to only source from top global manufacturers that we trust, that way you never have to worry about the reliability or authenticity of our items.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-237-1073 Item Description: Transformer Power | 5950 | 002371073 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Nes-4107 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.120 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.245 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.875 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ADAQ | BODY LENGTH | 6.250 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 24.5 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY89.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY28.00 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY28.00 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND NINE SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 18876-10668614 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 37 TAB, SOLDER LUG |
![]() |